Van Steenburgh

Engineering Laboratories

 

Refrigerant Management Products

Over 25 Years Serving the Industry Worldwide

Steenburgh Engineering Laboratories
 

Additional Features

  • 30 lb. / 13.6 kg cylinder for convenient recovery and storage 
  • Oil sight glass on compressor
  • Float valve safety shut off on external cylinder adds safety 
  • Laboratory quality gauges
  • Automatic system pumps down to required vacuum levels allowing immediate changeover to a different refrigerant

 

 

Specifications

 

Dimensions

W - 23in / 58.4 cm

D - 19 in / 48.26 cm

H - 33 in / 83.8 cm

     (with wheels)

 

Weight

121 lbs / 44.5 kg (approx)

 

Compressor

One-half horsepower Hermetic

 

Refrigerant

R12, R22, R134a, R401A, R401B, R402A, R402B, R404A, R407C, R408A, R409A, R411A, R411B, R412A, R414A, R414B, R416A, R500, R502...and more

 

Recovery Capacity

1.1 lbs. / .5 kg liquid per minute

vapor slightly less

 

Electrical

115/120 60Hz, 1 Ph

Alternate voltage available

 

Amperage

10 amp service required

 

Storage Capacity

30 lbs. / 13.6 kg external cylinder

 

Pressure Gauges

laboratory quality

 

In/Out Valves

1/4 in. / 6.3 mm SAE male flare

 

Wheels

10 in. OD / 25.4cm OD

                                      Series RV                                     

 Refrigerant Recovery System

  • Unbeatable for rapid & numerous changing of refrigerants
  • Fast recovery of the refrigerant charge
  • Powder coated steel cabinet
  • One Half Horsepower Hermetic Compressor
  • Pumps to EPA vacuum levels with no harm to the compressor
  • Patented Liquid Injection
  • 30 lb / 13.6 kg external recovery cylinder
  • UL listed
  • Exclusive Van Steenburgh Engineering inlet separator

Versatile Design

For the customer whose daily business results in servicing equipment with many different refrigerants and a need for portability-this is the machine for their application. This machine provides versatility and a lighter weight design while retaining the cleaning desirability. This machine meets these needs by eliminating the on-board storage feature of our Reclaim Systems.

 

Recovery Machine That Thinks It's a Recycle Machine

The Van Steenburgh Recovery System is a natural by-product of the worldwide accepted Van Steenburgh Refrigerant Reclaim Systems. The RV-10 integrates the same rugged dependability that has made our systems the standard of comparison worldwide for over 15 years.

 

 

Maximum Separation

The Van Steenburgh system provides maximum separation of oil, acid, moisture and hard particle contaminants through its unique method of pumping the refrigerant liquid or vapor at high velocity and high temperature into the separation chamber as it drops to near zero velocity. This causes the oil, acid, water and hard particle contaminants to drop to the bottom where they can be retrieved along with the maximum amount of retrievable oil.

No other system does this

 

 

Drying/Filtering

Special OEM filter/driers provide maximum moisture removal resulting in an exceptionally dry refrigerant leaving the system.

No other system does this

 

Pump Vapor

The Van Steenburgh system employs patented Compressor Liquid Injection during vapor removal. This means we pump a cylinder or system to atmospheric pressure without harm to the compressor. Get those last pounds, don't send them back to the vendor.

No other system does this

       Recovery Systems: move refrigerants from one place to another.

    Recycle Systems: capture refrigerants and do some cleaning

       Reclaim Systems: return refrigerants to virgin (purity) specifictions , meeting ARI 700 Standards for resale