Van Steenburgh

Engineering Laboratories

 

Refrigerant Management Products

Over 25 years Serving the Industry Worldwide

Steenburgh Engineering Laboratories
 

Additional Features

  • Unique multiple thermal expansion valves
  • Oil sight glass on compressor
  • Float valve safety shut off to prevent over filling
  • Laboratory quality gauges
  • Visual check points to monitor drying
  • Straight through capability

 

 

Specifications

 

Dimensions

W - 28in / 71.1 cm

D - 24 in / 61.0 cm

H - 60 in /152.4 cm

     (with caster)

 

Weight

460 lbs / 209 kg (approx)

 

Compressor

Two horsepower Hermetic

 

Refrigerants

R12, R22, R134a, R401A, R401B, R402A, R402B, R404A, R407C, R408A, R409A, R410A, R410B, R411A, R411B, R412A, R414A, R414B, R416A, R500, R502...and more

 

Reclaim Capacity

5 lbs. / 2.3 kg liquid per minute

vapor slightly less

 

Control Circuit

112/120 VAC 60 Hz

 

Electrical

208/230, 60 Hz, 1 Ph (unit voltage )

Alternate voltage available

 

Amperage

20 amp service required

 

Storage Capacity

90 lbs. / 41 kg

 

Pressure Gauges

laboratory quality

 

In/Out Valves

1/4 in. / 6.3 mm SAE male flares

(3/8 in. / 9.5 mm also available)

 

Casters

5 in. / 12.7 heavy-duty ball bearing

 

Series JV   

Ideal for In-Shop Work

  • Ideal for In-Shop work 
  • Manufactured to customers specifications with options to handle R12, R134a, R22, R502 & R500 and most alternates in the same range with one machine utilizing a unique multiple expansion valve design
  • Two Horsepower Hermetic Compressor
  • Pumps to required vacuum levels with no harm to the compressor
  • Patented Liquid Injection
  • Measurable oil out facilitating the servicing process
  • Performance results exceed the requirements for Maximum Allowable Levels of Contaminants as outlined in ARI Standard 1999
  • Refrigerants which have been cleaned will pass the purity testing process required for resale
  • UL listed
  • Available with self-clearing option facilitating rapid and multiple changing of refrigerants while retaining speed and the on board storage feature

Maximum Separation

The Van Steenburgh system provides maximum separation of oil, acid, moisture and hard particle contaminants through its unique method of pumping the refrigerant liquid or vapor at high velocity and high temperature into the separation chamber as it drops to near zero velocity. This causes the oil, acid, water and hard particle contaminants to drop to the bottom where they can be retrieved along with the maximum amount of retrievable oil.

No other system does this

 

Sub-Cooling

The vapor from the separator passes through the compressor to the air condenser where it is condensed to liquid. It then passes to the Chill Chambers where it is sub-cooled to 15 to 40 degrees F/-9 or 4 degrees F C. This aids in the transfer of the refrigerant to a cylinder or system at room temperature or warmer. It also enhances the drying/filtering process.

No other system does this

 

Drying/Filtering

Sub-cooled refrigerant dries more efficiently. We take advantage of this by recirculating the sub-cooled refrigerant at the rate of 300-400 lbs. / 136.3 to 181.8 kg an hour (based on ambient range). This means maximum drying.

No other system does this

 

Pump Vapor

The Van Steenburgh system employs patented Compressor Liquid Injection during vapor removal. This means we pump a cylinder or system to atmospheric pressure without harm to the compressor. Get those last pounds, don't send them back to the vendor.

No other system does this

 

Non-Condensable Separation

The combination of sub cooling and the on-board storage where the refrigerant is constantly being re-circulated, means maximum separation. The "air out" switch allows you to purge all non-condensables.

No other system does this

   Recovery Systems: move refrigerants from one place to another.

   Recycle Systems: capture refrigerants and do some cleaning

       Reclaim Systems: return refrigerants to virgin (purity) specifictions , meeting ARI 700 Standards for resale